{"id":1370,"date":"2026-05-16T06:09:25","date_gmt":"2026-05-16T06:09:25","guid":{"rendered":"https:\/\/serverdimm.com\/?p=1370"},"modified":"2026-05-16T06:12:39","modified_gmt":"2026-05-16T06:12:39","slug":"how-to-size-server-memory-for-vdi-environments","status":"publish","type":"post","link":"https:\/\/serverdimm.com\/fr\/how-to-size-server-memory-for-vdi-environments\/","title":{"rendered":"Comment dimensionner la m\u00e9moire des serveurs pour les environnements VDI ?"},"content":{"rendered":"<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h2>Table des mati\u00e8res<\/h2><nav><ul><li><a href=\"#the-dirty-secret-most-vdi-memory-plans-are-fiction\">Le vilain secret : la plupart des plans de m\u00e9moire VDI sont de la fiction<\/a><\/li><li><a href=\"#the-baseline-formula-i-would-actually-use\">La formule de base que j'utiliserais r\u00e9ellement<\/a><\/li><li><a href=\"#vmware-horizon-citrix-and-avd-do-not-save-bad-math\">VMware Horizon, Citrix et AVD ne sauvent pas les mauvais calculs<\/a><\/li><li><a href=\"#the-failover-number-nobody-wants-to-budget\">Le num\u00e9ro de basculement que personne ne veut budg\u00e9ter<\/a><\/li><li><a href=\"#capacity-is-not-the-same-as-compatibility\">La capacit\u00e9 n'est pas la m\u00eame chose que la compatibilit\u00e9<\/a><\/li><li><a href=\"#the-sizing-table-what-i-would-put-in-front-of-finance\">Le tableau des tailles : Ce que je mettrais devant la finance<\/a><\/li><li><a href=\"#the-vdi-memory-sizing-workflow-i-trust\">Le processus de dimensionnement de la m\u00e9moire VDI auquel je fais confiance<\/a><ul><li><a href=\"#step-1-segment-users-before-sizing-hosts\">\u00c9tape 1 : Segmenter les utilisateurs avant de dimensionner les h\u00f4tes<\/a><\/li><li><a href=\"#step-2-measure-working-set-not-assigned-ram\">\u00c9tape 2 : Mesurer l'ensemble de travail, pas la RAM assign\u00e9e<\/a><\/li><li><a href=\"#step-3-model-concurrency-honestly\">\u00c9tape 3 : Mod\u00e9liser honn\u00eatement la concurrence<\/a><\/li><li><a href=\"#step-4-add-platform-overhead\">\u00c9tape 4 : Ajouter le plafond de la plate-forme<\/a><\/li><li><a href=\"#step-5-add-n-1-or-n-2-failover\">\u00c9tape 5 : Ajouter le basculement N+1 ou N+2<\/a><\/li><li><a href=\"#step-6-match-memory-modules-to-the-platform\">\u00c9tape 6 : Adapter les modules de m\u00e9moire \u00e0 la plate-forme<\/a><\/li><li><a href=\"#step-7-pilot-before-bulk-deployment\">\u00c9tape 7 : Essai pilote avant le d\u00e9ploiement en masse<\/a><\/li><\/ul><\/li><li><a href=\"#the-procurement-traps-that-break-vdi-projects\">Les pi\u00e8ges de l'approvisionnement qui font \u00e9chouer les projets VDI<\/a><\/li><li><a href=\"#faqs\">FAQ<\/a><ul><li><a href=\"#what-is-vdi-memory-sizing\">Qu'est-ce que le dimensionnement de la m\u00e9moire VDI ?<\/a><\/li><li><a href=\"#how-do-i-calculate-memory-for-vdi\">Comment calculer la m\u00e9moire pour la VDI ?<\/a><\/li><li><a href=\"#how-much-ram-does-a-vdi-server-need\">De quelle quantit\u00e9 de m\u00e9moire vive un serveur VDI a-t-il besoin ?<\/a><\/li><li><a href=\"#is-4gb-ram-enough-for-a-vdi-user\">Une m\u00e9moire vive de 4 Go est-elle suffisante pour un utilisateur VDI ?<\/a><\/li><li><a href=\"#what-matters-more-for-vdi-ram-speed-or-ram-capacity\">Qu'est-ce qui compte le plus pour la VDI : la vitesse ou la capacit\u00e9 de la m\u00e9moire vive ?<\/a><\/li><li><a href=\"#should-vdi-hosts-use-ecc-rdimm-or-lrdimm\">Les h\u00f4tes VDI doivent-ils utiliser des RDIMM ECC ou des LRDIMM ?<\/a><\/li><\/ul><\/li><li><a href=\"#final-thoughts-build-the-vdi-memory-plan-before-you-buy-the-dimms\">R\u00e9flexions finales : \u00c9laborer le plan de m\u00e9moire VDI avant d'acheter les modules DIMM<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-400838a\" id=\"gspb_image-id-gsbp-400838a\"><img decoding=\"async\" src=\"https:\/\/serverdimm.com\/wp-content\/uploads\/2026\/05\/How-to-Size-Server-Memory-for-VDI-Environments2.jpeg\" data-src=\"\" alt=\"Comment dimensionner la m\u00e9moire des serveurs pour les environnements VDI ?\" loading=\"lazy\" width=\"750\" height=\"750\"\/><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-dirty-secret-most-vdi-memory-plans-are-fiction\">Le vilain secret : la plupart des plans de m\u00e9moire VDI sont de la fiction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Commencez par les utilisateurs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La plupart des feuilles de calcul de dimensionnement de la m\u00e9moire VDI semblent professionnelles parce qu'elles contiennent des lignes, des formules et quelques hypoth\u00e8ses bien rang\u00e9es, mais la v\u00e9ritable faiblesse est g\u00e9n\u00e9ralement enfouie dans une cellule paresseuse : \u201cRAM moyenne par utilisateur\u201d, copi\u00e9e d'un ancien pilote, arrondie \u00e0 l'inf\u00e9rieur pour prot\u00e9ger le budget, et jamais test\u00e9e contre les connexions du lundi matin. Qui signe cela et s'attend \u00e0 des tickets d'assistance calmes ?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Je ne fais pas confiance aux moyennes dans la VDI. Je fais confiance \u00e0 la simultan\u00e9it\u00e9, \u00e0 l'ensemble de travail mesur\u00e9, aux temp\u00eates de d\u00e9marrage, au comportement des profils, \u00e0 la politique graphique, \u00e0 la synchronisation de l'antivirus, aux limites NUMA et \u00e0 l'horrible question \u00e0 laquelle aucune diapositive de fournisseur ne veut r\u00e9pondre : que se passe-t-il lorsqu'un h\u00f4te dispara\u00eet \u00e0 9 h 12 du matin ?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C'est l\u00e0 que le dimensionnement de la m\u00e9moire VDI devient r\u00e9el.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le site de Microsoft <a href=\"https:\/\/learn.microsoft.com\/en-us\/windows-server\/remote\/remote-desktop-services\/session-host-virtual-machine-sizing-guidelines\" rel=\"nofollow noopener\" target=\"_blank\">conseils sur le dimensionnement de la machine virtuelle de l'h\u00f4te de session<\/a> fait la m\u00eame remarque de mani\u00e8re polie : le type de charge de travail, le nombre d'utilisateurs, les besoins en ressources, les d\u00e9lais de connexion et la marge de man\u0153uvre ont tous leur importance, et Microsoft pr\u00e9vient que les machines virtuelles peuvent repr\u00e9senter un co\u00fbt de capacit\u00e9 de 15 \u00e0 20% par rapport aux machines nues, tandis que les temps de r\u00e9ponse des utilisateurs peuvent \u00eatre sup\u00e9rieurs de 10 \u00e0 20% en raison de la surcharge de l'hyperviseur. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Donc, non, \u201c100 utilisateurs \u00d7 4GB = 400GB\u201d n'est pas un plan. Il s'agit d'une serviette de table avec des probl\u00e8mes de confiance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-baseline-formula-i-would-actually-use\">La formule de base que j'utiliserais r\u00e9ellement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Voici la version propre :<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>M\u00e9moire totale de l'h\u00f4te = m\u00e9moire VM\/session + r\u00e9serve OS\/hyperviseur + graphique\/profil\/cache + marge de man\u0153uvre pour le basculement + tampon op\u00e9rationnel<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cela semble ennuyeux.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les bonnes tailles sont ennuyeuses.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le mauvais dimensionnement devient excitant au moment pr\u00e9cis o\u00f9 la finance, les op\u00e9rations et le DSI se demandent tous pourquoi la nouvelle infrastructure de bureau virtuel semble plus lente que les ordinateurs portables qu'elle a remplac\u00e9s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour un premier mod\u00e8le de dimensionnement de la RAM VDI, je diviserais la population d'utilisateurs en quatre classes de travail :<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Classe d'utilisateurs<\/th><th>Applications typiques<\/th><th>Hypoth\u00e8se de RAM de d\u00e9part par utilisateur<\/th><th>Notes que je n'ignorerais pas<\/th><\/tr><\/thead><tbody><tr><td>Travailleur \u00e0 la t\u00e2che<\/td><td>Navigateur, \u00e9cran ERP, Office l\u00e9ger<\/td><td>2-3GB<\/td><td>Observer la croissance des onglets du navigateur et le comportement de d\u00e9lestage des \u00e9quipes<\/td><\/tr><tr><td>Travailleur du savoir<\/td><td>Office, navigateur, PDF, CRM, light BI<\/td><td>4-6GB<\/td><td>La plupart des \u201cutilisateurs moyens\u201d sont vraiment ici, pas dans le seau \u00e0 lumi\u00e8re<\/td><\/tr><tr><td>Utilisateur exp\u00e9riment\u00e9<\/td><td>Mod\u00e8les Excel, PDF volumineux, bases de donn\u00e9es locales, outils de d\u00e9veloppement<\/td><td>8-12GB<\/td><td>La pression de la m\u00e9moire peut augmenter rapidement pendant les p\u00e9riodes de d\u00e9claration<\/td><\/tr><tr><td>Utilisateur graphique \/ ing\u00e9nieur<\/td><td>Visionneuse CAO, 3D, SIG, vid\u00e9o, outils de conception<\/td><td>12-32GB<\/td><td>La m\u00e9moire tampon du GPU, le profil vGPU et le nombre d'affichages modifient les calculs.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Ce tableau ne remplace pas les mesures. Il permet d'arr\u00eater de pr\u00e9tendre que tous les utilisateurs se comportent de la m\u00eame mani\u00e8re.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le tableau Azure Virtual Desktop de Microsoft fournit des points d'ancrage utiles : les exemples de sessions simples l\u00e9g\u00e8res, moyennes et lourdes correspondent respectivement \u00e0 2 vCPU\/8GB RAM, 4 vCPU\/16GB RAM et 8 vCPU\/32GB RAM ; pour les h\u00f4tes multisessions, Microsoft sugg\u00e8re un nombre maximal d'utilisateurs par vCPU de 6 pour les charges l\u00e9g\u00e8res, 4 pour les charges moyennes et 2 pour les charges lourdes, avec 8 vCPU\/16GB RAM comme configuration minimale de la VM pour ces exemples. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Voici la dure v\u00e9rit\u00e9 : le CPU est souvent bl\u00e2m\u00e9 en premier parce que les graphiques du CPU sont bruyants, mais la m\u00e9moire est l'endroit o\u00f9 la VDI devient silencieusement m\u00e9chante. Une fois que l'h\u00f4te commence \u00e0 gonfler, compresser, \u00e9changer, paginer ou punir le stockage parce que la RAM \u00e9tait sous-dimensionn\u00e9e, l'utilisateur ne dit pas \u201ccontention de la m\u00e9moire\u201d. L'utilisateur dit : \u201cLa VDI est une poubelle\u201d.\u201d<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vmware-horizon-citrix-and-avd-do-not-save-bad-math\">VMware Horizon, Citrix et AVD ne sauvent pas les mauvais calculs<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un courtier n'est pas magique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">VMware Horizon, Citrix Virtual Apps and Desktops et Azure Virtual Desktop peuvent tous \u00eatre bien con\u00e7us, mais aucun d'entre eux n'annule l'arithm\u00e9tique ; si l'h\u00f4te a 768 Go install\u00e9s et que votre demande r\u00e9elle \u00e0 l'\u00e9tat stable plus la demande de basculement est de 850 Go, la marque de la plateforme ne change que le logo sur le rapport d'incident. Pourquoi tant d'\u00e9quipes continuent-elles \u00e0 faire leurs achats en fonction du nom de la plateforme avant les preuves de la charge de travail ?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour le dimensionnement de la m\u00e9moire de VMware Horizon, je commencerais par l'affectation du syst\u00e8me d'exploitation du poste de travail, la conception du profil, le protocole d'affichage et le mod\u00e8le de pool. Les postes de travail persistants se comportent diff\u00e9remment des pools non persistants. Windows 10 et Windows 11 se comportent diff\u00e9remment apr\u00e8s les mises \u00e0 jour. Un \u201cpoint de d\u00e9part\u201d de 2 Go pour un poste de travail de base peut figurer dans la documentation du fournisseur, mais une fois que les applications Microsoft 365, l'isolation du navigateur, Teams, la synchronisation OneDrive, les agents de s\u00e9curit\u00e9 et les conteneurs de profil arrivent, ce chiffre devient un plancher, et non un objectif de production.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les exigences de RAM de Citrix VDI, la politique HDX et les graphiques sont importants. Les exigences syst\u00e8me actuelles de Citrix pour HDX 3D Pro indiquent que l'ordinateur h\u00f4te doit disposer d'au moins 4 Go de RAM et de quatre vCPU \u00e0 2,3 GHz ou plus, et Citrix note \u00e9galement des conseils sur les p\u00e9riph\u00e9riques utilisateurs tels que 4 Go de RAM minimum et 8 Go de RAM pour des performances optimales du c\u00f4t\u00e9 des terminaux. Ce d\u00e9tail sur les terminaux ne dimensionne pas le serveur, mais il nous rappelle que l'affichage, le GPU et le comportement de la session font partie de la cha\u00eene compl\u00e8te. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En ce qui concerne Azure Virtual Desktop, les conseils de Microsoft sont utiles parce qu'ils indiquent clairement la partie la plus discr\u00e8te : la planification de la capacit\u00e9 doit couvrir le type de charge de travail, le nombre d'utilisateurs simultan\u00e9s, les besoins en ressources, les p\u00e9riodes de connexion, les pics de charge et la marge de man\u0153uvre.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mon avis : si votre plan VDI n'inclut pas un calcul de l'h\u00f4te d\u00e9faillant, il ne s'agit pas d'une planification de la capacit\u00e9. C'est de l'optimisme en mati\u00e8re de capacit\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-failover-number-nobody-wants-to-budget\">Le num\u00e9ro de basculement que personne ne veut budg\u00e9ter<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Prenons un exemple concret.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Supposez 400 travailleurs intellectuels simultan\u00e9s. Vous mesurez, et non devinez, et vous trouvez un objectif r\u00e9aliste de 5 Go de RAM par session active une fois qu'Office, le navigateur, les applications m\u00e9tier, l'activit\u00e9 du conteneur de profil et l'outil de s\u00e9curit\u00e9 se sont stabilis\u00e9s.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">M\u00e9moire de la session de base :<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>400 utilisateurs \u00d7 5GB = 2 000GB<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ajoutez maintenant la plate-forme et la r\u00e9serve d'exploitation. J'ai l'habitude de s\u00e9parer ces deux \u00e9l\u00e9ments, car le fait de cacher la r\u00e9serve dans le num\u00e9ro d'utilisateur cr\u00e9e de mauvais arguments par la suite.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Exemple de r\u00e9serve :<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>2 000 GIGAOCTETS \u00d7 15% = 300 GIGAOCTETS<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ajoutez maintenant un tampon op\u00e9rationnel pour les temp\u00eates de connexion, les bizarreries des jours de correctifs, le gonflement des navigateurs et le bruit de la surveillance :<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>2 300 GIGAOCTETS \u00d7 20% = 460 GIGAOCTETS<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sous-total :<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>2 760 GO<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ajoutez maintenant le basculement N+1. Si vous utilisez 5 h\u00f4tes et qu'un h\u00f4te tombe en panne, les 4 autres doivent absorber la charge. Cela signifie que l'objectif de capacit\u00e9 utilisable par h\u00f4te n'est pas le total de la RAM install\u00e9e divis\u00e9 par la demande du chemin heureux. Il s'agit de la demande totale divis\u00e9e par les h\u00f4tes survivants.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><code>2 760 Go \u00f7 4 h\u00f4tes survivants = 690 Go de m\u00e9moire utilisable par h\u00f4te<\/code><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cela ne signifie pas qu'il faille installer exactement 690 Go. Cela signifie que le plan de m\u00e9moire de votre serveur doit tenir compte des r\u00e8gles de population de m\u00e9moire, de l'\u00e9quilibre des canaux, de la taille des modules DIMM, de l'expansion future et du fait qu'un serveur \u00e0 deux sockets n'aime pas le chargement n\u00e9glig\u00e9 des emplacements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C'est ici que je cesserais de lire les brochures et que je commencerais \u00e0 v\u00e9rifier la strat\u00e9gie r\u00e9elle du module : <a href=\"https:\/\/serverdimm.com\/fr\/categorie-produit\/ddr4-server-memory\/\">M\u00e9moire serveur DDR4<\/a> pour les mises \u00e0 jour courantes qui fonctionnent encore sur des plates-formes d'entreprise \u00e9tendues, <a href=\"https:\/\/serverdimm.com\/fr\/categorie-produit\/ddr5-server-memory\/\">M\u00e9moire serveur DDR5<\/a> pour les nouveaux h\u00f4tes \u00e0 densit\u00e9 \u00e9lev\u00e9e, et <a href=\"https:\/\/serverdimm.com\/fr\/quality-warranty\/\">v\u00e9rification de la compatibilit\u00e9 de la m\u00e9moire du serveur<\/a> avant que quiconque n'ach\u00e8te une palette de modules en se basant uniquement sur la capacit\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"capacity-is-not-the-same-as-compatibility\">La capacit\u00e9 n'est pas la m\u00eame chose que la compatibilit\u00e9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Un module DIMM de 64 Go peut toujours \u00eatre le mauvais module DIMM de 64 Go.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les environnements VDI, je m'int\u00e9resse aux ECC RDIMM par rapport aux LRDIMM, aux DDR4 par rapport aux DDR5, aux 2Rx4 par rapport aux 4Rx4, \u00e0 l'\u00e9quilibre des canaux, aux DIMM par canal, au downclocking de la vitesse de la m\u00e9moire, \u00e0 la g\u00e9n\u00e9ration du CPU, \u00e0 la prise en charge du BIOS et au fait que le devis mentionne le num\u00e9ro de pi\u00e8ce exact du fabricant ou simplement une \u00e9tiquette de capacit\u00e9 sympathique. Il s'agit l\u00e0 d'une question d'hygi\u00e8ne en mati\u00e8re d'approvisionnement, et non d'une question de nerd.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les pages de ServerDIMM consacr\u00e9es \u00e0 la m\u00e9moire pour serveurs montrent pourquoi le chemin d'acc\u00e8s interne est important : le site distingue les nouvelles m\u00e9moires DDR4, les nouvelles m\u00e9moires DDR5, les m\u00e9moires d'occasion, les marques telles que Samsung, Micron, Kingston et SK Hynix, ainsi que les supports de qualit\u00e9 et de garantie pour l'examen de la compatibilit\u00e9 et les tests. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour un h\u00f4te VDI, je pr\u00e9f\u00e9rerais acheter une vitesse de t\u00eate l\u00e9g\u00e8rement inf\u00e9rieure et obtenir une capacit\u00e9 valid\u00e9e, des canaux \u00e9quilibr\u00e9s, un comportement ECC et une documentation RMA propre. Le commerce inverse rel\u00e8ve de l'amateurisme.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L'\u00e9tude de production de Google <a href=\"https:\/\/research.google\/pubs\/dram-errors-in-the-wild-a-large-scale-field-study\/\" rel=\"nofollow noopener\" target=\"_blank\">Erreurs de DRAM dans la nature<\/a> a constat\u00e9 des erreurs de m\u00e9moire dans un grand parc de serveurs sur une p\u00e9riode de 2,5 ans, couvrant plusieurs millions de jours DIMM, avec des taux d'erreur DRAM observ\u00e9s de 25 000 \u00e0 70 000 erreurs par milliard d'heures d'appareil par Mbit et plus de 8% de DIMM affect\u00e9s par des erreurs par an. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une \u00e9tude ult\u00e9rieure du centre de donn\u00e9es de production Alibaba\/CUHK, <a href=\"https:\/\/www.cse.cuhk.edu.hk\/~pclee\/www\/pubs\/srds22.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Une \u00e9tude corr\u00e9lative approfondie entre les erreurs de DRAM et les pannes de serveur<\/a>, a analys\u00e9 plus de 3 millions de modules de m\u00e9moire dans 250 000 serveurs sur une p\u00e9riode de huit mois, y compris 2 137 pannes de serveurs caus\u00e9es par des erreurs de DRAM ; l'article a r\u00e9v\u00e9l\u00e9 que pour plus de 40% de ces pannes, des erreurs de DRAM corrigibles sont apparues dans l'heure qui a pr\u00e9c\u00e9d\u00e9 la panne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C'est pourquoi je ne consid\u00e8re pas l'ECC, la validation et la clart\u00e9 des lots comme facultatifs. Dans une VDI dense, un probl\u00e8me de m\u00e9moire n'est pas le probl\u00e8me d'un seul utilisateur. C'est un g\u00e9n\u00e9rateur de plaintes \u00e0 l'\u00e9chelle de l'\u00e9tage.<\/p>\n\n\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-1437800\" id=\"gspb_image-id-gsbp-1437800\"><img decoding=\"async\" src=\"https:\/\/serverdimm.com\/wp-content\/uploads\/2026\/05\/How-to-Size-Server-Memory-for-VDI-Environments1.jpeg\" data-src=\"\" alt=\"Comment dimensionner la m\u00e9moire des serveurs pour les environnements VDI ?\" loading=\"lazy\" width=\"750\" height=\"750\"\/><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-sizing-table-what-i-would-put-in-front-of-finance\">Le tableau des tailles : Ce que je mettrais devant la finance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Voici un tableau de planification brutal des besoins en m\u00e9moire des serveurs VDI. Il ne s'agit pas d'une nomenclature finale. Il s'agit d'une amorce de conversation qui permet d'\u00e9viter une densit\u00e9 fantaisiste.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Sc\u00e9nario<\/th><th>Exemple de nombre d'utilisateurs<\/th><th>Objectif de RAM par utilisateur<\/th><th>M\u00e9moire active de base<\/th><th>Ajouter une r\u00e9serve et un tampon<\/th><th>V\u00e9ritable note de planification<\/th><\/tr><\/thead><tbody><tr><td>Postes de travail l\u00e9gers group\u00e9s<\/td><td>300<\/td><td>3GB<\/td><td>900GB<\/td><td>1,2-1,4 TO<\/td><td>S\u00fbr uniquement si le navigateur, les \u00e9quipes et les agents de s\u00e9curit\u00e9 sont contr\u00f4l\u00e9s<\/td><\/tr><tr><td>VDI pour travailleurs intellectuels<\/td><td>400<\/td><td>5GB<\/td><td>2TB<\/td><td>2,6-3,0 TO<\/td><td>La plupart des d\u00e9ploiements de bureaux atterrissent ici apr\u00e8s avoir \u00e9t\u00e9 mesur\u00e9s<\/td><\/tr><tr><td>Pool d'utilisateurs<\/td><td>150<\/td><td>10GB<\/td><td>1,5 TO<\/td><td>2,0-2,4 TO<\/td><td>Moins de densit\u00e9, plus de satisfaction<\/td><\/tr><tr><td>Graphique VDI<\/td><td>80<\/td><td>20GB<\/td><td>1,6 TO<\/td><td>2,2 TO +<\/td><td>Le profil vGPU, le nombre d'\u00e9crans et le comportement de l'application d\u00e9terminent le nombre final.<\/td><\/tr><tr><td>Domaine mixte<\/td><td>600<\/td><td>Segment\u00e9<\/td><td>Ne pas faire la moyenne \u00e0 l'aveuglette<\/td><td>Mod\u00e8le par personne<\/td><td>Une grande moyenne cache les utilisateurs qui enfreignent la ferme<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">J'obligerais \u00e9galement le service financier \u00e0 se pencher sur le calcul des pannes. L'Uptime Institute <a href=\"https:\/\/datacenter.uptimeinstitute.com\/rs\/711-RIA-145\/images\/2024.GlobalDataCenterSurvey.Report.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Enqu\u00eate mondiale sur les centres de donn\u00e9es 2024<\/a> a indiqu\u00e9 que 54% des personnes interrog\u00e9es ont d\u00e9clar\u00e9 que leur derni\u00e8re panne importante avait co\u00fbt\u00e9 plus de $100 000, tandis que 20% ont d\u00e9clar\u00e9 une panne de plus de $1 million.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comparez maintenant ce chiffre au co\u00fbt de l'ajout d'une marge de man\u0153uvre avant le d\u00e9ploiement. Soudain, \u201ctrop de RAM\u201d semble moins inutile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Et le march\u00e9 de la m\u00e9moire n'est pas tr\u00e8s favorable. Reuters a rapport\u00e9 le 5 janvier 2026 que la demande d'infrastructures d'IA avait provoqu\u00e9 une p\u00e9nurie mondiale de m\u00e9moires, les prix de certaines m\u00e9moires ayant plus que doubl\u00e9 depuis f\u00e9vrier 2025 et les analystes s'attendant \u00e0 ce que la reprise se poursuive jusqu'en 2027. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mon conseil d'achat est donc simple : ne pas sous-dimensionner maintenant et supposer une expansion bon march\u00e9 plus tard. Cette hypoth\u00e8se a du mordant.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-vdi-memory-sizing-workflow-i-trust\">Le processus de dimensionnement de la m\u00e9moire VDI auquel je fais confiance<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-1-segment-users-before-sizing-hosts\">\u00c9tape 1 : Segmenter les utilisateurs avant de dimensionner les h\u00f4tes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ne commencez pas par \u201c500 utilisateurs\u201d. Commencez par les utilisateurs de t\u00e2ches, de connaissances, de pouvoir, de graphiques, de kiosques, d'entrepreneurs, de d\u00e9veloppeurs et de cadres. Oui, les cadres comptent. Ils sont souvent les premiers \u00e0 remarquer que les connexions sont lentes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-2-measure-working-set-not-assigned-ram\">\u00c9tape 2 : Mesurer l'ensemble de travail, pas la RAM assign\u00e9e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La m\u00e9moire vive attribu\u00e9e est un plafond. L'ensemble de travail est un comportement. Suivez l'utilisation de la m\u00e9moire pendant la connexion, le travail r\u00e9gulier, les r\u00e9unions vid\u00e9o, les fen\u00eatres de rapport, les p\u00e9riodes de navigation intensive et les \u00e9critures de profil de fin de journ\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-3-model-concurrency-honestly\">\u00c9tape 3 : Mod\u00e9liser honn\u00eatement la concurrence<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un domaine de 1 000 utilisateurs peut avoir 620 sessions simultan\u00e9es de pointe. Ou 910. La diff\u00e9rence r\u00e9side dans l'achat de mat\u00e9riel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-4-add-platform-overhead\">\u00c9tape 4 : Ajouter le plafond de la plate-forme<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Il s'agit d'ESXi, de vSphere, d'Hyper-V, d'AHV, du syst\u00e8me d'exploitation de l'h\u00f4te, des agents de surveillance, de l'EDR, des outils de sauvegarde, des gestionnaires de vGPU et de tout ce qui se trouve sur ou autour de l'h\u00f4te.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-5-add-n-1-or-n-2-failover\">\u00c9tape 5 : Ajouter le basculement N+1 ou N+2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si vous ne pouvez pas survivre \u00e0 une perte d'h\u00f4te, inscrivez-le dans le registre des risques. Ne le cachez pas dans la feuille de calcul.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-6-match-memory-modules-to-the-platform\">\u00c9tape 6 : Adapter les modules de m\u00e9moire \u00e0 la plate-forme<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Utilisez le mod\u00e8le de serveur exact, la g\u00e9n\u00e9ration de CPU, le guide de population DIMM, le type de module pris en charge, le rang et la vitesse. Lorsque la nomenclature devient s\u00e9rieuse, j'utiliserais ServerDIMM's <a href=\"https:\/\/serverdimm.com\/fr\/\">fournisseur de RAM pour serveur en vrac<\/a> chemin pour la planification du volume, puis v\u00e9rification crois\u00e9e <a href=\"https:\/\/serverdimm.com\/fr\/quality-warranty\/\">les tests de qualit\u00e9 et l'aide \u00e0 la garantie<\/a> avant le d\u00e9ploiement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"step-7-pilot-before-bulk-deployment\">\u00c9tape 7 : Essai pilote avant le d\u00e9ploiement en masse<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pilotez avec de vrais utilisateurs, et non avec du personnel informatique qui se comporte gentiment pour un test. Capturez les donn\u00e9es de charge de type Login VSI si vous les avez. Utilisez la surveillance native si vous n'en avez pas. Mais mesurez.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"the-procurement-traps-that-break-vdi-projects\">Les pi\u00e8ges de l'approvisionnement qui font \u00e9chouer les projets VDI<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le premier pi\u00e8ge consiste \u00e0 m\u00e9langer la m\u00e9moire avec la RAM d'un ordinateur de bureau. Les h\u00f4tes VDI ne sont pas des PC de jeu avec une activit\u00e9 secondaire. Les r\u00e8gles RDIMM et LRDIMM sont importantes. La sym\u00e9trie des canaux est importante. La population de sockets de l'unit\u00e9 centrale est importante.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le deuxi\u00e8me pi\u00e8ge consiste \u00e0 acheter en fonction de la vitesse plut\u00f4t que de l'ad\u00e9quation. Un module DDR5-5600 peut s'entra\u00eener moins vite en fonction du CPU, de la population de DIMM par canal, du BIOS et des r\u00e8gles de la plate-forme. Si le serveur fonctionne en DDR5-4800 dans votre configuration, l'autocollant n'a pas menti, c'est votre hypoth\u00e8se qui l'a fait.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le troisi\u00e8me pi\u00e8ge consiste \u00e0 confondre bon march\u00e9 et contr\u00f4le. La RAM d'occasion peut s'av\u00e9rer tout \u00e0 fait judicieuse dans le cadre de projets de maintenance ou d'expansion, mais uniquement lorsque l'origine, les tests, la classe de modules et la compatibilit\u00e9 sont g\u00e9r\u00e9s de mani\u00e8re transparente. C'est pourquoi <a href=\"https:\/\/serverdimm.com\/fr\/categorie-produit\/used-branded-memory\/ddr4-server-memory\/\">M\u00e9moire serveur DDR4 utilis\u00e9e<\/a> et <a href=\"https:\/\/serverdimm.com\/fr\/categorie-produit\/used-branded-memory\/ddr5-server-memory\/\">M\u00e9moire serveur DDR5 utilis\u00e9e<\/a> doivent \u00eatre \u00e9valu\u00e9es comme des options d'approvisionnement contr\u00f4l\u00e9es, et non comme des suppositions d'aubaine.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ma r\u00e8gle : si le devis ne peut pas m'indiquer la capacit\u00e9 exacte, la g\u00e9n\u00e9ration DDR, l'\u00e9tat ECC, la classe RDIMM\/LRDIMM, le rang, la vitesse, la marque, le num\u00e9ro de pi\u00e8ce, l'\u00e9tat test\u00e9 et le processus de garantie, ce n'est pas un devis de m\u00e9moire VDI. Il s'agit d'un document de transfert de risque.<\/p>\n\n\n\n<div class=\"wp-block-greenshift-blocks-image gspb_image gspb_image-id-gsbp-ffaaa7b\" id=\"gspb_image-id-gsbp-ffaaa7b\"><img decoding=\"async\" src=\"https:\/\/serverdimm.com\/wp-content\/uploads\/2026\/05\/How-to-Size-Server-Memory-for-VDI-Environments.jpeg\" data-src=\"\" alt=\"Comment dimensionner la m\u00e9moire des serveurs pour les environnements VDI ?\" loading=\"lazy\" width=\"750\" height=\"750\"\/><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"faqs\">FAQ<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-is-vdi-memory-sizing\">Qu'est-ce que le dimensionnement de la m\u00e9moire VDI ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le dimensionnement de la m\u00e9moire VDI consiste \u00e0 calculer la quantit\u00e9 de m\u00e9moire vive du serveur physique n\u00e9cessaire pour prendre en charge les bureaux virtuels ou les sessions publi\u00e9es dans des conditions r\u00e9elles de charge de travail, de concurrence, de surcharge et de basculement. Il comprend la demande de m\u00e9moire par utilisateur, la r\u00e9serve de l'hyperviseur, le comportement du profil, les exigences graphiques, la m\u00e9moire tampon op\u00e9rationnelle et la planification de la capacit\u00e9 de perte d'h\u00f4te.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En clair, il r\u00e9pond \u00e0 une question : les utilisateurs disposeront-ils encore d'un bureau utilisable lorsque tout le monde se connectera, que les applications deviendront lourdes et qu'un h\u00f4te tombera en panne ?<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-do-i-calculate-memory-for-vdi\">Comment calculer la m\u00e9moire pour la VDI ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Vous calculez la m\u00e9moire pour la VDI en multipliant les utilisateurs simultan\u00e9s par la demande de RAM mesur\u00e9e par utilisateur, puis en ajoutant la r\u00e9serve de l'hyperviseur, les frais g\u00e9n\u00e9raux du syst\u00e8me d'exploitation du bureau, les frais g\u00e9n\u00e9raux des graphiques ou des profils, la marge op\u00e9rationnelle et la capacit\u00e9 de basculement. Le mod\u00e8le le plus s\u00fbr s\u00e9pare les classes de charge de travail des utilisateurs au lieu d'appliquer une moyenne \u00e0 l'ensemble de l'environnement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une formule pratique est la suivante : <code>utilisateurs simultan\u00e9s \u00d7 RAM par utilisateur + 15-25% de r\u00e9serve + 20-30% de m\u00e9moire tampon + N+1 failover<\/code>. Il faut ensuite le valider dans le cadre d'un projet pilote.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"how-much-ram-does-a-vdi-server-need\">De quelle quantit\u00e9 de m\u00e9moire vive un serveur VDI a-t-il besoin ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Un serveur VDI a besoin de suffisamment de m\u00e9moire vive pour prendre en charge les postes de travail virtuels ou les sessions qui lui sont attribu\u00e9s lors des pics de fr\u00e9quentation, tout en laissant de la place pour les frais g\u00e9n\u00e9raux de l'hyperviseur, les temp\u00eates de connexion, le basculement et les op\u00e9rations de maintenance. Dans de nombreux environnements professionnels, cela signifie des centaines de gigaoctets \u00e0 plusieurs t\u00e9raoctets par cluster h\u00f4te, et non un nombre universel unique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Un h\u00f4te \u00e0 deux sockets avec 512 Go peut convenir \u00e0 un pool et \u00eatre imprudent pour un autre. C'est la charge de travail qui d\u00e9cide.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"is-4gb-ram-enough-for-a-vdi-user\">Une m\u00e9moire vive de 4 Go est-elle suffisante pour un utilisateur VDI ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Une RAM de 4 Go peut \u00eatre suffisante pour un utilisateur VDI l\u00e9ger ou mod\u00e9r\u00e9 ex\u00e9cutant des applications bureautiques contr\u00f4l\u00e9es, mais elle est souvent trop faible pour un travail moderne n\u00e9cessitant un navigateur, Microsoft 365 Apps, Teams, des agents de s\u00e9curit\u00e9 et des conteneurs de profil. Consid\u00e9rez 4 Go comme une hypoth\u00e8se de d\u00e9part, et non comme une preuve de l'aptitude \u00e0 la production.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Je le testerais en fonction du temps de connexion r\u00e9el et du comportement r\u00e9el du navigateur avant de le d\u00e9fendre lors d'une revue de conception.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"what-matters-more-for-vdi-ram-speed-or-ram-capacity\">Qu'est-ce qui compte le plus pour la VDI : la vitesse ou la capacit\u00e9 de la m\u00e9moire vive ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La capacit\u00e9 de la RAM est g\u00e9n\u00e9ralement plus importante que la vitesse de la RAM pour la VDI lorsque l'environnement est soumis \u00e0 une pression de m\u00e9moire, car le swapping, le ballooning et la pagination nuisent \u00e0 l'exp\u00e9rience de l'utilisateur de mani\u00e8re plus visible que de petites diff\u00e9rences dans la fr\u00e9quence de la m\u00e9moire. La vitesse reste importante sur les plateformes modernes et denses, mais la capacit\u00e9 valid\u00e9e et la population correcte sont prioritaires.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Je pr\u00e9f\u00e8re utiliser des RDIMM ECC stables dans une configuration \u00e9quilibr\u00e9e plut\u00f4t que de courir apr\u00e8s des MT\/s que le serveur ne peut pas maintenir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"should-vdi-hosts-use-ecc-rdimm-or-lrdimm\">Les h\u00f4tes VDI doivent-ils utiliser des RDIMM ECC ou des LRDIMM ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les h\u00f4tes VDI doivent utiliser le type de m\u00e9moire pris en charge par la plateforme du serveur, le plus souvent ECC RDIMM pour les configurations d'entreprise classiques et LRDIMM lorsqu'une capacit\u00e9 plus \u00e9lev\u00e9e par h\u00f4te est requise et officiellement prise en charge. Les m\u00e9moires RDIMM et LRDIMM ne doivent pas \u00eatre m\u00e9lang\u00e9es, \u00e0 moins que la documentation de la plate-forme ne prenne explicitement en charge cette configuration exacte.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour la VDI de production, \u201c\u00e7a rentre dans la fente\u201d n'est pas une question de compatibilit\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"final-thoughts-build-the-vdi-memory-plan-before-you-buy-the-dimms\">R\u00e9flexions finales : \u00c9laborer le plan de m\u00e9moire VDI avant d'acheter les modules DIMM<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Voici ma position d\u00e9finitive : Le dimensionnement de la m\u00e9moire VDI n'est pas un exercice d'achat. Il s'agit d'un exercice de pr\u00e9vention des pannes d\u00e9guis\u00e9 en nomenclature.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Commencez par segmenter les utilisateurs. Mesurer l'ensemble de travail. Ajoutez une marge de man\u0153uvre. Mod\u00e9lisez la survie de l'h\u00f4te d\u00e9faillant. Respectez les directives de VMware Horizon, Citrix et Azure Virtual Desktop, mais ne laissez pas les minimums des fournisseurs devenir votre objectif de production. Ensuite, achetez la RAM du serveur comme un adulte : type de module exact, comportement ECC, r\u00e8gles de population, clart\u00e9 du num\u00e9ro de pi\u00e8ce, inventaire test\u00e9, et un chemin de garantie qui ne dispara\u00eetra pas lorsque le d\u00e9ploiement commencera.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour l'\u00e9tape suivante, cr\u00e9ez une feuille de travail d'une page sur la m\u00e9moire VDI avec les classes d'utilisateurs, les pics de concurrence, les objectifs de RAM par utilisateur, le nombre d'h\u00f4tes, le basculement N+1 et la configuration DIMM cible. Envoyez ensuite le mod\u00e8le de serveur, la g\u00e9n\u00e9ration du processeur, la configuration actuelle de la m\u00e9moire, la capacit\u00e9 cible, la classe de module DDR4 ou DDR5 pr\u00e9f\u00e9r\u00e9e et la quantit\u00e9 par l'interm\u00e9diaire de l'interface de ServerDIMM <a href=\"https:\/\/serverdimm.com\/fr\/contact\/\">contact et chemin d'acc\u00e8s au devis<\/a> afin que la compatibilit\u00e9 puisse \u00eatre v\u00e9rifi\u00e9e avant que l'approvisionnement ne se transforme en d\u00e9pannage.<\/p>","protected":false},"excerpt":{"rendered":"<p>Le dimensionnement de la m\u00e9moire VDI \u00e9choue lorsque les \u00e9quipes comptent les utilisateurs au lieu des ensembles de travail. Voici un guide brutal de la RAM serveur pour VDI, avec des formules, des exemples de dimensionnement, une marge de man\u0153uvre pour le basculement et les pi\u00e8ges de l'approvisionnement qui nuisent au temps de fonctionnement.<\/p>","protected":false},"author":1,"featured_media":1371,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"#gspb_image-id-gsbp-1437800 img,#gspb_image-id-gsbp-400838a img,#gspb_image-id-gsbp-ffaaa7b img{vertical-align:top;display:inline-block;box-sizing:border-box;max-width:100%;height:auto}","footnotes":""},"categories":[24],"tags":[428,201,202,274,425,429,423,426,424,427],"class_list":["post-1370","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications-solutions","tag-citrix-vdi-ram-requirements","tag-ddr4-server-memory","tag-ddr5-server-memory","tag-ecc-rdimm","tag-server-ram-for-vdi","tag-vdi-capacity-planning","tag-vdi-memory-sizing","tag-vdi-ram-sizing","tag-vdi-server-memory-requirements","tag-vmware-horizon-memory-sizing"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/posts\/1370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/comments?post=1370"}],"version-history":[{"count":1,"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/posts\/1370\/revisions"}],"predecessor-version":[{"id":1374,"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/posts\/1370\/revisions\/1374"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/media\/1371"}],"wp:attachment":[{"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/media?parent=1370"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/categories?post=1370"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/serverdimm.com\/fr\/wp-json\/wp\/v2\/tags?post=1370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}